Standard Construction Detail Change Record
ST-01 – Sidewalk Detail (01/28/21) – PDF
ST-02-04 – Concrete Driveway Detail, Residential, Commercial/Multi-family, Ribbon Curb/Rural, and speed less/greater than 45 MPH (01/28/21) – PDF
ST-05-07 – Laydown and Ribbon Curb, Spill/Catch Curb, Concrete Valley Gutter Detail (01/28/21) – PDF
ST-08 – Short Wall (01/28/21) – PDF
ST-09-11 – C.I.P Moveable Sign and Construction Site Sign (01/28/21) – PDF
ST-12-13 – Street End Marker Detail and Street End Barricade (01/28/21) – PDF
ST-14-15 – Typical Section HMAC and CPCD (01/28/21) – PDF
ST-16 – Fire Lane Marking Detail (01/28/21) – PDF
ST-17-18 – Bus Stop and Pad Detail (01/28/21) – PDF
ST-19-23 – Bicycle Rack Installation in Concrete Paver/Sidewalk – Alternate 1/2 (01/28/21) – PDF
ST-24 – Steel Plating (01/28/21) – PDF
ST-25 – Safety Fence (01/28/21) – PDF
ST-26-28 – Survey Marker Subdivision Lot/Permanent Monument (01/28/21) – PDFST-29 – Standard 10′ and 15′ Curb Inlet (01/28/21) – PDF
EC-01 – Tree Protection Notes (01/28/21) – PDF
EC-02 – Tree Protection Tree Wells (01/28/21) – PDF
EC-03 – Tree Protection Fence Locations (01/28/21) – PDF
EC-04 – Tree Protection Fence, Chain Link (01/28/21) – PDF
EC-05 – Interceptor Swale Detail (03/25/11) – AutoCAD – PDF
EC-06 – Diversion Dike Detail (03/25/11) – AutoCAD – PDF
EC-07 – Pipe Slope Drain Detail (03/25/11) – AutoCAD – PDF
EC-08 – Level Spreader Detail (03/25/11) – AutoCAD – PDF
EC-09 – Stabilized Construction Entrance Detail (03/25/11) – AutoCAD – PDF
EC-10 – Silt Fence Detail (03/25/11) – AutoCAD – PDF
EC-11 – Triangular Sediment Filter Dike Detail (03/25/11) – AutoCAD – PDF
EC-12 – Rock Berm Detail (03/25/11) – AutoCAD – PDF
EC-13 – Curb Inlet Protection with Erosion Control Log Detail (03/25/11) – AutoCAD – PDF
EC-14 – Curb Inlet Protection Detail (03/25/11) – AutoCAD – PDF
EC-15 – Area Inlet Protection Detail (03/25/11) – AutoCAD – PDF
EC-16 – Area Inlet Protection with Erosion Control Log Detail (03/25/11) – AutoCAD – PDF
EC-17 – Erosion Control Log Detail (03/25/11) – AutoCAD – PDF
- DU-01 – Dry Utility Details General Notes (01/28/21) – PDF
- DU-02 – Unpaved Area Trench (UAT) Detail (01/28/21) – PDF
- DU-03 – Asphalt Paved Area Trench (APAT) Detail (01/28/21) – PDF
- DU-04 – Proposed Pavement Area Trench (PPAT) Detail (01/28/21) – PDF
- DU-05 – Utility Crossing Installation (UC) Detail (01/28/21) – PDF
- DU-06 – Standard Utility Assignments within Residential Development Detail (01/28/21) – PDF
- DU-07 – Random Lay Joint Trench Detail; electric, telephone, cable & gas (01/28/21) – PDF
- DU-08 – Installation of Street Lighting on Major Urban Pavement with 12″ x 12″ Pull Box Detail (01/28/21) – PDF
- DU-09 – Dry Utility Bore Under Existing Roadway (01/28/21) – PDF
- DR-01 – Storm Sewer Line Bedding Detail, existing paved surface (04/01/10) – AutoCAD – PDF
- DR-02 – Storm Sewer Line Bedding Detail, non-paved surface (04/01/10) – AutoCAD – PDF
- DR-03 – Concrete Trickle Channel Detail (04/01/10) – AutoCAD – PDF
- DR-04 – French Drain Detail, existing paved surface (04/01/10) – AutoCAD – PDF
- DR-05 – Storm Sewer Manhole Cover and Frame Detail, bolted (04/01/10) – AutoCAD – PDF
- DR-06 – Storm Sewer Manhole Cover and Frame Detail, non-bolted (04/01/10) – AutoCAD – PDF
- DR-07 – Storm Sewer Inlet Cover and Frame Detail (04/01/10) – AutoCAD – PDF
WT-19 – 8″ to 12″ Fire Service Compound Water Meter Assembly Detail(NOT USED) (01/19/15) – PDF
- WW-01 – Precast Concrete Wastewater Manhole Detail (03/01/18) – AutoCAD – PDF
- WW-02 – Precast Concrete Wastewater Manhole with Drop Connection Detail (03/01/18) – AutoCAD – PDF
- WW-03 – Precast Concrete Wastewater Manhole with Drop Service Detail (03/01/18) – AutoCAD – PDF
- WW-04 – Cast-in-Place Base for Concrete Wastewater Manhole Detail (03/01/18) – AutoCAD – PDF
- WW-05 – Manhole Vent for Below Ground Installation Detail (Developed Areas) (03/01/18) – AutoCAD – PDF
- WW-06 – Manhole Vent for Above Ground Installation Detail (Undeveloped Areas) (03/01/18) – AutoCAD – PDF
- WW-07 – Bolted Wastewater Manhole Cover and Frame Detail (03/01/18) – AutoCAD – PDF
- WW-08 – Non-Bolted Wastewater Manhole Cover and Frame Detail (03/01/18) – AutoCAD – PDF
- WW-09 – Precast 48″ Concentric Concrete Cone Section Detail (03/01/18) – AutoCAD – PDF
- WW-10 – Flexible “Seal Boot” Resilient Connector Detail (03/01/18) – AutoCAD – PDF
- WW-11 – Wastewater Flow Patterns for Invert Channels Detail (03/01/18) – AutoCAD – PDF
- WW-12 – Wastewater Service Detail (03/01/18) – AutoCAD – PDF
- WW-13 – Wastewater Service Clean-Out Detail (Paved Surface) (03/01/18) – AutoCAD – PDF
- WW-14 – Wastewater Service Clean-Out Detail (Non-Paved Surface) (03/01/18) – AutoCAD – PDF
- WW-15 – Wastewater Manhole Abandonment Detail (03/01/18) – AutoCAD – PDF
- WW-16 – Wastewater Lateral Connection to Existing Wastewater Main Detail (03/01/18) – AutoCAD – PDF
- WW-17 – Wastewater Line Bedding and Surface Repair Detail (Existing Paved Surface) (03/01/18) – AutoCAD – PDF
- WW-18 – Wastewater Line Bedding and Surface Repair Detail (Non-Paved and Proposed Paved Surface) (03/01/18) – AutoCAD – PDF
- WW-19 – Manhole Marker Signage Detail (03/01/18) – AutoCAD – PDF
- WW-20 – Concrete Trench Cap Detail (03/01/18) – AutoCAD – PDF
- WW-21 – Existing Wastewater Manhole Connection Detail (03/01/18) – AutoCAD – PDF
- RW-01 – Single 5/8″, 3/4″ or 1″ Reuse Water Meter Detail (03/01/18) – AutoCAD – PDF
- RW-02 – Single 1 1/2″ or 2″ Reuse Water Meter Detail (03/01/18) – AutoCAD – PDF
- RW-03 – Dual 5/8″, 3/4″ or 1″ Reuse Water Meters Detail (03/01/18) – AutoCAD – PDF
- RW-04 – 4″ or 6″ Reuse Water Domestic Compound Meter Assembly Detail (03/01/18) – AutoCAD – PDF
- RW-05 – Reuse Water Gate Valve Detail (03/01/18) – AutoCAD – PDF
- RW-06 – Reuse Water Valve Box Assembly Detail (03/01/18) – AutoCAD – PDF
- RW-07 – 1″ Thru 2″ Air Release Valve Installation Detail (Developed Areas) (03/01/18) – AutoCAD – PDF
- RW-08 – 1″ Thru 2″ Air Release Valve Installation Detail (Undeveloped Area) (03/01/18) – AutoCAD – PDF
- RW-09 – Reuse Water Bolted Wastewater Manhole Cover and Frame Detail (03/01/18) – AutoCAD – PDF
- RW-10 – Reuse Water Pressure Reducing Valve Vault Details (03/01/18) – AutoCAD – PDF
NOTE: All 6 detail pages must be included in your construction plans as a complete set - RW-11 – Reuse Water Sign Detail (03/01/18) – AutoCAD – PDF
- RW-12 – Reuse Water Irrigation Sign Detail (03/01/18) – AutoCAD – PDF
- RW-13 – Reuse Water Valve Sign Detail (03/01/18) – AutoCAD – PDF
Contact us for questions regarding these details
City of Round Rock Transportation Department
Ed Polasek
Senior Planner
3400 Sunrise Road
Round Rock, TX 78665
512-341-3167